Use the Following Hyperlink to Access Kalwall Online Specifications: http://www.kalwall.com/spec.htm A SUMMARY OF SPECIFICATIONS Panel Width: 4' and 5' (1220mm and 1500mm) standard. Other widths up to 5' 0" (1500mm) are optional. Panel Length: 3' to 20' (914mm to 6096mm) standard, 16' max. (5000mm) for skyroofs. Panel Thickness: 2-3/4" (70mm), 1-9/16" (40mm), 1" (30mm) and 5/8" (16mm) thick glazing panels available Weight: 1-1/2 to 2 pounds per square foot (72 to 96 Pa/m2) Color: Crystal, White, Optional Kal-tint Panels, translucent insulation can be virtually any color to create dazzling results Surface Texture: flat or pebble Grid Pattern: 12" x 24" (300mm x 600mm), reverse, 8" x 20" (200mm x 500mm), 10" x 10" (250mm x 250mm), 12" x 12" (300mm x 300mm) Tuckerman Materials: FRP faces, aluminum faces, aluminum grid, composite grid, fiberglass insulation, aluminum and thermally broken installation systems U-Value Range: .53 to .05 (U-value SI conversion: 1.0 w/m2k=0.176 BTU/(hr / ft2 / ÁF)) Light Range: 0 to 65% Impact Resistance: 60 ft.lbs. (81J) up to South Florida Missile Impact Options Chemical Resistance: Most anything allowed by EPA and OSHA Weathering: Virtually no color change or maintenance, full thickness colorfast permanent glass veil erosion barrier, fully field restorable for infinite life Sound: Average transmitted by test, excellent performance Fire: Exceeds all basic Codes for Plastics and optional versions meet many performance requirements for other uses, e.g., Class A Built-up Roof and Class 1 FM Panels
Kalwall Light Transmission, Solar Heat Gain Coefficients and U-Values Kalwall is a composite sandwich; various combinations are possible, and test data should be interpreted from this point of view. Consult Sales Service Department for further clarification. Since this table is of a very technical nature, please consult your heating and ventilation engineer for proper interpretation. Listed below are the light transmission, solar heat gain coefficients and U-values for some Kalwall Panel face sheet combinations. Others are available. Blue values indicate thermally broken panels. thermally broken panels.
U-value SI conversion: 1.0 w/m2k = 0.176 BTU/(hr•ft2•°F)
Shading Coefficient (SC) is equal to 1.15 times the Solar Heat Gain Coefficient (SHGC).
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|